STARTEX CHEMICAL INC -- XYLENE -- 6810-00-584-4070
===================== Product Identification =====================
Product ID:XYLENE
MSDS Date:06/15/1995
FSC:6810
NIIN:00-584-4070
=== Responsible Party ===
Company Name:STARTEX CHEMICAL INC
Address:5 HACKBERRY LANE
Box:3087
City:CONROE
State:TX
ZIP:77305
Country:US
Info Phone Num:409-539-6244
Emergency Phone Num:409-539-6244/800-424-9300(CHEMTREC)
CAGE:0YFV5
=== Contractor Identification ===
Company Name:STARTEX CHEMICAL INC
Address:5 HACKBERRY LANE
Box:3087
City:CONROE
State:TX
ZIP:77305
Country:US
Phone:409-539-6244
CAGE:0YFV5
============= Composition/Information on Ingredients =============
Ingred Name:XYLENES (O-,M-,P- ISOMERS) (SARA 313) (CERCLA)
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 85.0%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:100 PPM
ACGIH TLV:100 PPM/150STEL;9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:ETHYL BENZENE (SARA 313)
CAS:100-41-4
RTECS #:DA0700000
Fraction by Wt: 15.0%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:100 PPM
ACGIH TLV:100 PPM/125STEL;9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:IRIT,DOES NOT INJURE EYE
TISSUE.SKIN:PREQ/PROL CONTACT MAY IRRIT.LOW ORDER OF
TOXICITY.OCCASIONAL BRIEF CONTACT W/LIQ WILL NOT RESULT IN
SIGNIFICANT IRRIT UNLESS EVAPORATION IS IMPEDED.INHAL:HI VA
P/AEROSOL CONC IRRIT EYES,RESP
TRACT,HEAD,DIZZ,ANESTHESIA,DROWS,UNCONSC,OTHER CNS EFFECTS INCLUDE
DEATH.LOW ORDER(SUPPL)
Effects of Overexposure:EYE IRRIT, SKIN IRRIT, IRRIT RESP TRACT,
HEADACHE, DIZZINESS, ANESTHESIA, DROWSINESS, UNCONSC, CNS EFFECTS,
DEATH. ASPIRATED INTO LUNGS CAUSE MILD TO SEVERE PULMONARY INJURY.
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE AN
EXISTING DERMATITIS CONDITION.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH W/LG AMTS OF WATER TIL IRRIT SUBSIDES.IRRIT
PERSISTS GET MED ATTN.SKIN:FLUSH W/LG AMTS OF WATER.USE SOAP IF
AVAILABLE.REMOVE GROSSLY CONTAMIN CLOTH INCLUDING SHOES.INHAL:USING
PROPER RESP PR OTECTION IMMED REMOVE AFFECTED VICTIM FROM
EXPO.ADMINISTER ART RESP IF BREATH STOP.KEEP @REST.CALL FOR PROMPT
MED ATTN.INGEST:DO NOT INDUCE VOMIT.KEEP @REST.GET PROMPT MED ATTN.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:81.0F,27.2C
Autoignition Temp:Autoignition Temp Text:932F
Lower Limits:1.9
Upper Limits:12.3
Extinguishing Media:USE FOAM OR DRY CHEMICAL TO EXTINGUISH FIRE.
Fire Fighting Procedures:COOL FIRE EXPO SURFACES/PROT PEOPLE.DISPERSE
VAP FROM LEAK/SPILL W/WATERSPRAY.RESP/EYE PROT REQUIRED FOR
FIREFIGHT PERSON.AVOID SPRAY WATER INTO CNTNR-BOILOVER.
Unusual Fire/Explosion Hazard:FLAMM LIQ,CAN RELEASE VAP THAT FORM FLAMM
MIXTURES @TEMP @/>FLASH PT.STATIC DISCHAR MATL CAN ACCUMULATE
STATIC CHARGES-CAN CAUSE INCENDIARY ELEC DISCHAR.(SUPPL)
================== Accidental Release Measures ==================
Spill Release Procedures:ELIMINATE IGN SOURCES.STOP LEAK/SPILL W/O
RISK.IMPLEMENT CLEANUP PROCEDURES.KEEP PUBLIC WAY.ADIVSE
AUTHORITIES.IF SUBJ TO CERCLA REPORTING NOTIFY NAT RESP
CNTR.PREVENT ENTER SEWERS/WATERCOURSE/LOW ARE AS.CONTAIN
W/SAND/EARTH.DON'T USE COMBUST (SUPPLE)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:EMPTIED CNTNRS MAY BE HAZ.SINCE
EMPTIED CNTNRS RETAIN RESIDUE(LIQ/VAP/SOILD)ALL HAZ PRECAUT GIVEN
MUST BE OBSERVED.
Other Precautions:WARNING!SUDDEN RELEASE OF HOT ORG CHEM VAP/MIST FROM
PROCESS EQPMT OPERATING @ELEVATED TEMP/PRESSURE/SUDDEN INGRESS OF
AIR INTO VAC EPQMT MAY RESULT IN IGN W/O PRESENCE OF OBVIOUS IGN
SOURCES.ANY USE OF PROD IN ELEVATED TEMP PROCESSES(SUPP)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WHERE CONC IN AIR MAY EXCEED LIMITS GIVEN THIS
SECTION & ENGINEERING WORK PRACTICE OR OTHER MEANS OF EXPO
REDUCTION ARE NOT ADEQUATE NIOSH/MSHA APPROVED RESPIRATORS MAY BE
NECESSARY TO PREVENT OVEREXP O BY INHAL.
Ventilation:LOC EXHAU VENTI RECOMMENDED TO CONTROL PROCESS EMISSIONS
NEAR SOURCE.LAB SPL IN HOOD.MECH VENTI CONFINE SPACE.EXPLO-PROF
Protective Gloves:CHEM-RESISTANT GLOVES.
Eye Protection:SAFETY GLASSE W/SIDE SHIELDS
Other Protective Equipment:LONG SLEEVES.
Work Hygienic Practices:LAUNDER CONTAMIN CLOTH/SHOES BEF REUSE.
Supplemental Safety and Health
FIRE/EXPLO HAZ:LIQ VOLATILE,INVISIBLE VAP,LOW AREA SETTLE.HEALTH
HAZ:TOXICITY. SPILL:MATL(SAWDUST).RECOVE BY PUMP/SUITABLE
ABSORBENT.CONSULT EXPERT ON DISPO.WATER SPILL:IF ALLOWED
SINK/SUITABLE DISPER SANTS USED IN NON-CONFINED WATERS. OTHER
PRECAUT:SHOULD BE WELL EVALUATED TO ESTABLISH & MAINTAIN SAFE OPER
CONDITION.
================== Physical/Chemical Properties ==================
HCC:F4
Boiling Pt:B.P. Text:283F,139C
Melt/Freeze Pt:M.P/F.P Text:-31F,-35C
Decomp Temp:Decomp Text:NP
Vapor Pres:14 @100F
Vapor Density:NP
Spec Gravity:0.87 @60F
pH:NP
Viscosity:0.7CST @77F
Evaporation Rate & Reference:0.8, (N-BUTYL ACETATE=1)
Solubility in Water:0.02, NELGIGIBLE.
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:NP
Corrosion Rate:NP
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS,CONC NITRIC & SULPHURIC ACIDS, HALOGEN, AND
MOLTEN SULPHUR.
Stability Condition to Avoid:TEMPERATURE ABOVE AMBIENT.
Hazardous Decomposition Products:TOXIC GASES WILL FORM UPON COMBUSTION.
FUMES, SMOKE, CARBON MONOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:EMPTY DR SHOULD BE COMPLETELY DRAINED/PROPERLY
BUNGED/PROMPTLY RETURNED TO DR RECONDITINER/PROPERLY DISPO OF.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.