POLYCHEM -- DEFOAMER 86 -- 6850-00N023336
=====================  Product Identification  =====================

Product ID:DEFOAMER 86
MSDS Date:09/23/1991
FSC:6850
NIIN:00N023336
=== Responsible Party ===
Company Name:POLYCHEM
Address:519 B STREET
City:SAN RAFAEL
State:CA
ZIP:94901
Country:US
Info Phone Num:415-485-2711
Emergency Phone Num:415-485-2711
Preparer's Name:MICHEAL FOLEY
CAGE:POLYC
=== Contractor Identification ===
Company Name:POLYCHEM
Address:519 B STREET
Box:City:SAN RAFAEL
State:CA
ZIP:94901
Country:US
Phone:415-485-2711
CAGE:POLYC

=============  Composition/Information on Ingredients  =============

Ingred Name:NON HAZARDOUS INGREDIENTS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MILD IRRITATION. CHRONIC: MILD
    IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:INHAL:IRRITATION TO THE MUCOUS MEMBRANES
    POSSIBLE. NO INJURY FROM RELATIVELY SHORT EXPOSURE. SKIN/EYES: MAY
    CAUSE TEMPORARY DISCOMFORT. SKIN ABSORB: MILD IRRITATION. INGEST:
    AMOUNTS TRANSFERRED TO THE	MOUTH BY FINGERS, ETC., DURING NORMAL
    OPERATIONS SHOULD NOT CAUSE INJURY.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:CALL MD. EYE:IMMED FLUSH W/H*2O FOR @ LST 15 MIN WHILE
    HOLDING LIDS AWAY FROM EYES. SKIN:IMMED FLUSH W/H*2O FOR @ LST 15
    MIN WHILE REMOVING ALL CONTAM CLTHG. WASH UNTIL 'SLIPPERY' FEELING
    IS GONE FROM  AFFECTED AREAS. INHAL:REMOVE TO FRESH AIR. IF NOT
    BRTHG, GIVE ART RESP, PREFERABLY MOUHT-TO-MOUTH. IF BRTHG IS DFCLT,
    GIVE O*2. INGEST:TAKE IMMED TO A HOSPITAL/MD. IF UNCON, TAKE IMMED
    TO (SUPP DATA)

=====================  Fire Fighting Measures  =====================

Extinguishing Media:WATER SPRAY, FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
    PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:WASH AWAY WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:NONE SPECIFIED BY MANUFACTURER.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED MECHANICAL FILTER FOR
    EXPOSURE TO MISTS.
Ventilation:LOCAL EXHAUST: ADEQUATE VENTILATION.
Protective Gloves:RUBBER.
Eye Protection:CHEM WORK GOGG/FULL LENGTH FSHLD .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NORMAL GOOD HOUSEKEEPING PRACTICES.
Supplemental Safety and Health
FIRST AID PROC: A HOSPITAL/MD. DO NOT INDUCE VOMITING/GIVE ANYTHING BY
    MOUTH TO AN UNCONSCIOUS PERSON.

==================  Physical/Chemical Properties  ==================

HCC:N1
Boiling Pt:B.P. Text:225F,107C
Vapor Pres:1.4 @ 20C
Vapor Density:2
Spec Gravity:1.08
Solubility in Water:COMPLETE
Appearance and Odor:HAZY LIQUID

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:CONTACT WITH STRONG OXIDIZERS.
Hazardous Decomposition Products:SILICONE DIOXIDE AND CO*2.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE AT APPROVED HAZARDOUS WASTE FACILITY.
    DISPOSE OF ALL WASTES IN ACCORANCE WITH FEDERAL, STATE, AND LOCAL
    REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.